header en 4
Image scroller
3D ratbrain & brainatlas anim2 Screenshot_of_the_BrainLOC_software skull_and_skin_01a vestib-3d-1 3D ratbrain & brainatlas anim1 BrainMOD5 IMG_5712 mig-b3-betweenness-pat brachy2 mri-pet-malac
News

No current events.

Login



Search
Counters

Visits today:35
Visits yesterday:113
Visits in this month:638
Visits in prev. month:2394
Visits total:203288
Max.daily visits:2541
Day of max visits:10-09-2023
Top 7: (last 3 months)
Unknown flag 47.7%Unknown (4153)
United States flag 43.3%United States (3776)
Hungary flag 7.3%Hungary (639)
Sweden flag <1.0%Sweden (32)
Germany flag <1.0%Germany (21)
Russian Federation flag <1.0%Russian Federation (20)
France flag <1.0%France (10)
8715 visits from 29 countries
Poll
Rate Our Website
 
HungarianEnglish
You are here:Workgroups»Developing Workgroup of Experimental Radiopharmaceuticals»Developing Workgroup of Experimental Radiopharmaceuticals

Warning: Creating default object from empty value in /site/joomla/components/com_k2/models/item.php on line 445

Developing Workgroup of Experimental Radiopharmaceuticals

Rate this item
(0 votes)

The workgroup was established to support the activity of the Biological Research Group to supply it with new radiolabelled compounds. With this object we have synthesized some well known radiotracers, such as 1-[18F]Fluoro-3-(2-nitroimidazol-1-yl)-propan-2-ol (18F-MISO), 9-[(4-[18F]Fluoro-3-hydroxymethybutyl)]guanine (18F-FHBG), O-(2-[18F]Fluoroethyl)-L-tyrosine (18F-FET), 3-(2-[18F]Fluoro)flumazenil. We participated in the radiolabelling of some biologically active macromolecules, such as oligonucleotides, serum albumins, Rhodamin B. We are especially interested in chemoselective radiolabelling of some, receptor specific peptide sequences, and we have fluorinated analogues for LH-RH-, somatostatin- and gastrin releasing peptide receptors starting the procedure from 18F-4-Fluorobenzaldehyde. This kind of ligation yields neutral peptide derivatives. If the radiolabelling is performed with radiometals, we get a positively charged peptide and this property will affect the biodistribution and clearance of the ligand. Therefore this approach can be interesting. With this object we are going to label receptor selective peptides with 68Ga.

We are also working on introduction of new, promising radiofluorination methods into our in-house practice. We have performed a couple of syntheses on 18F-Fluoroethyl tosylate using recently published reaction media, such as ionic liquids, bulky protic solvents. The goal of these experiments is to work out effective methods for aliphatic nucleophilic substitution.

staff...